Model NO.: AKNF2F-8040
Performance: Efficient Filtration
Certification: ISO 9001
Trademark: AQUCELL
Transport Package: Export Carton(Optional with Wooden Cases)
Specification: Diameter 8", Length 40"
Origin: China
HS Code: 84212990
Model NO.: AKNF2F-8040
Performance: Efficient Filtration
Certification: ISO 9001
Trademark: AQUCELL
Transport Package: Export Carton(Optional with Wooden Cases)
Specification: Diameter 8", Length 40"
Origin: China
HS Code: 84212990
Material Separation NF Membrane ElementBasic Parameter:
Membrane Active Area • • • 400 ft2(37.2m2)
Salt Rejection Rate • • • 96%
Recovery Rate of Single Membrane Element • • • 15%
Average Permeate Flow • • • 12000GPD (45.4m3/D)
Test Condition:
Test solution strength(NaCl) • • • 500ppm Test solution strength(MgSO4) • • • 2000ppm
Test solution temperature • • • 25ºC Test pressure • • • 70psi(0.48MPa)
Test solution PH value • • • 7.5-8 Individual element recovery rate • • • 15%
Operation limits:
Max operation pressure • • • 600psi(4.14MPa) Max Inlet water temperature • • • 45ºC
Max inlet water SDI • • • 5.0 Max chlorine tolerance • • • 0.1mg/L
Continuous operation PH range • • • 3-10 Chemical Enhanced Cleaning PH range• • • 2-11
Max element pressure drop • • • 10psi(0.07MPa)
Specification:
Model | A | B | C |
8040 | 1016.1mm(40.0in) | 201mm(7.9in) | 28.6mm(1.125in) |
Basic Parameter:
Membrane Active Area • • • 400 ft2(37.2m2)
Salt Rejection Rate • • • 96%
Recovery Rate of Single Membrane Element • • • 15%
Average Permeate Flow • • • 12000GPD (45.4m3/D)
Test Condition:
Test solution strength(NaCl) • • • 500ppm Test solution strength(MgSO4) • • • 2000ppm
Test solution temperature • • • 25ºC Test pressure • • • 70psi(0.48MPa)
Test solution PH value • • • 7.5-8 Individual element recovery rate • • • 15%
Operation limits:
Max operation pressure • • • 600psi(4.14MPa) Max Inlet water temperature • • • 45ºC
Max inlet water SDI • • • 5.0 Max chlorine tolerance • • • 0.1mg/L
Continuous operation PH range • • • 3-10 Chemical Enhanced Cleaning PH range• • • 2-11
Max element pressure drop • • • 10psi(0.07MPa)
Specification:
Model | A | B | C |
8040 | 1016.1mm(40.0in) | 201mm(7.9in) | 28.6mm(1.125in) |
Self Activated Balancing Valve
Dynamic equilibrium means
to control pressure change by some devices for system balance in variable flow system when
process loading changed from 0% to 100% .
The advantage of variable flow systems in dynamic equilibrium case is to save energy,
significantly enhance comfort, improve system efficiency and control
accuracy.
The Self-Acting DP Control balancing valve is used
for dynamic hydraulic balance of
heating and air conditioning systems. It can reduce
the complexity and time-consuming calibration process.
Activated Valve,Pressure Activated Valve,Self Activated Balancing Valve,Self-Actuated Differential Pressure Control Valve
A1BEST International Corporation , https://www.aone-best.com