1)Application
HPLC, IC, ICP-MS, TOC nanlysis, organic nanlysis, CF-AAS, Toxicology research, capillary electrophoresis,
Environmental protection experimental analysis
2)Flow schematic PF+KDF+AC+RO+UV+AC+DI+TF
LV. 1 5μ M spun fiber filter
LV. 2 Mixed KDF filter
LV. 3 Granular active carbon filter
LV. 4 100GPD RO membrane
LV. 5 Double (254&185nm) wavelength UV lamp
LV. 6 Post active carbon filter
LV. 7 Ultra pure polishing resin cartridge
LV. 8 (0.45+0.1)μ M importing PES terminal filter
3)After-sales
· The products customers buy from our company enjoy repair service since the day of purchase. In on year from the purchasing day, our company is obliged to replace components free of charge due to non-human-behavior factors except:
(1). Damage caused by maloperation or use in abnormal situations.
(2). Disassembly any part of the machine or human-behavior damage.
(3). Not repaired by our serviceman.
As a rich experience of pure water system manufacturer, Hitech uphold the common development concept with customers, and provide professional pre-sales support and after-sales service. We promise:
12months for maintenance(except consumables).
On site installation supervision.
Free system update service.
Periodically return service.
Service hotline-400.
HPLC, IC, ICP-MS, TOC nanlysis, organic nanlysis, CF-AAS, Toxicology research, capillary electrophoresis,
Environmental protection experimental analysis
2)Flow schematic PF+KDF+AC+RO+UV+AC+DI+TF
LV. 1 5μ M spun fiber filter
LV. 2 Mixed KDF filter
LV. 3 Granular active carbon filter
LV. 4 100GPD RO membrane
LV. 5 Double (254&185nm) wavelength UV lamp
LV. 6 Post active carbon filter
LV. 7 Ultra pure polishing resin cartridge
LV. 8 (0.45+0.1)μ M importing PES terminal filter
3)After-sales
· The products customers buy from our company enjoy repair service since the day of purchase. In on year from the purchasing day, our company is obliged to replace components free of charge due to non-human-behavior factors except:
(1). Damage caused by maloperation or use in abnormal situations.
(2). Disassembly any part of the machine or human-behavior damage.
(3). Not repaired by our serviceman.
As a rich experience of pure water system manufacturer, Hitech uphold the common development concept with customers, and provide professional pre-sales support and after-sales service. We promise:
12months for maintenance(except consumables).
On site installation supervision.
Free system update service.
Periodically return service.
Service hotline-400.
Model | Standard | Eliminating endotoxin | Low TOC | Comprehensive | |||
Master-S | Master-S UF | Master-S UV | Master-S UVF | ||||
Master-S plus | Master-S plus UF | Master-S plus UV | Master-S plus UVF | ||||
Flow procedure | PF+KDF+AC+RO+AC+DI+TF | PF+KDF+AC+RO+AC+DI+UF+TF | PF+KDF+AC+RO+UV+AC+DI+TF | PF+KDF+AC+RO+UV+AC+DI+UF+TF | |||
Application |
GC,HPLC,IC,ICP PCR, weather analysis Amino acid analysis Reagent preparation |
Molecular biology Cell and tissue cultivation Life science, IVF electrophoresis |
HPLC,IC,ICP-MS TOC and organism analysis CF-AAS, toxicology study Environmental analysis |
HPLC,IC,ICP-MS,CF-AAS, Physics, electrochemistry, Molecular biology, Cell cultivation | |||
Ultrapure water quality |
Resistivity | 18.2MΩ.cm@25ºC | |||||
Heavy metal ions | < 0.1ppb | ||||||
TOC | <10 ppb | <3 ppb | |||||
Bacteria | <1CFU/ml | ||||||
Endotoxin | - | <0.001EU/ml | - | <0.001EU/ml | |||
Particle(>0.22μm) | <1/ml | ||||||
RO water quality | < TDS(ppm, mg/l) of tap water×5% | ||||||
Technical specification |
Output(25 ºC ) | 15 Liters/hour* (plus model:30 Liters/hour*) | |||||
Flow rate | 2 liters/min(with pressure tank) | ||||||
Pure water outlet | RO water, ultrapure water | ||||||
Dimension/Weight | Length×Width×Height:50×36×54cm / 20-30Kg | ||||||
Electric requirements | AC110-220V,50/60Hz,120W | ||||||
Control system |
Mode display | Power on, program, inlet rinse, producing, full, circle, regular outlet, disinfection, consumables replacing remind | |||||
Safety | low pressure and full water alarm, password, auto-reset, outlet forbidden when alarm or disinfection | ||||||
System monitor | Monitoring quality of feed water, RO water and ultrapure water, temperature, used and left time of consumables | ||||||
Feed water requirement |
Tap water, inlet TDS<200 ppm,5-45ºC, 1.0-4.0 kgf/cm 2  (if inlet TDS>200ppm, extra pretreatment is recommended) |
||||||
Purification system |
Pretreatment unit | 5μm spun fiber filter×1+Kinetic degradation fluxion filter×1+Granular active carbon filter×1 | |||||
RO unit | 100 GPD RO membrane×1 ( Plus model:100 GPD RO membrane×2) | ||||||
Subsequent unit |
Post active carbon filter×1+Ultrapure polishing resin cartridge× 4+(0.45+0.1) μm terminal filter×1 UV model:+Double wavelength(185&254)nm UV lamp cartridge×1 UF model:+5000 Doulton UF cartridge×1 UVFmodel:+Double wavelength(185&254)nm UV lamp cartridge×1+5000 Doulton UF cartridge×1 |
||||||
Standard configuration | Main body(including:1 set cartridge)+4 gallon tank + accessory box |
Magnesium Hydroxide Coated (MDH-III)
Flame Retardant Cables,Magnesium Hydroxide Coated,Flame Retardant Exterior Paint,Fire Retardant Clothing Kit
SHANDONG TAIXING ADVANCED MATERIAL CO., LTD. , https://www.fr-chem.com