Model NO.: ZZDS-102
Power Source: Battery
Measure Method: Automatic
Capacity: 100/200/500g
Trademark: SAINT FIRE
Transport Package: Color Box
Specification: CE, ISO
Origin: Zhejiangyongkang
Model NO.: ZZDS-102
Power Source: Battery
Measure Method: Automatic
Capacity: 100/200/500g
Trademark: SAINT FIRE
Transport Package: Color Box
Specification: CE, ISO
Origin: Zhejiangyongkang
200g Electornic Pocket Scale Jewelry ScaleBule light
AC/DC power
LCD or LED Display
Kg/lb conversion available
Tare and Auto Zero Tracking
Capacity: 100/200/500g
Packing qty: 100PCS/CTN
G. W: 15kg
Specification:
1. Digit LED
2. Auto Power Shut Off
3. TARE peeled the function PCS counts the function, The UNIT UNIT conversion function, RIGHT background light display.
4. Gross weight, net weight: 114 g / 124 g/units
5. Power supply: 1.5 V (dry cell / 2)
6. A variety of display mode; G/oz/tl/ct, precision: soil (0.5% + of LSD)
7. Products' size: 120.4 mm / 62 mm / 20.3 mm
8. Pallet size: 56.3 mm / 50.2 m





Instructions
Turn on/off:
1. Put electronic scale smooth the surface of the table, and then press ON/OFF button (ON/OFF key), boot screen shows boot screen (backlight will automatically open) at the same time, the "0.00" will be displayed after about 1 second, can be normal use
2. Boot mode, according to an ON/OFF button (ON/OFF button) can be shut OFF the power
3. In order to prolong the service life of the battery, in the boot state, without any operation or display Numbers without any change, will automatically shut off the power supply in 60 seconds
Reset/peeling function:
1. Boot if not shown after the "0.00", press "TARE" button, display zero, can be normal use
2. If you want to use other container to weigh, please put the container on the scale, and then click on the "TARE" button shows that after the "0.00", put items on the capacity of product, display is the actual weight of goods; Get off after container will show a negative number, press "TARE" reset
Unit:
g ,oz,tl,ct
LCD:
Boot mode, according to the "LIGHT" in turn key, can open or close the backlight
tally function
Under the normal state of weighing, placed on the scale amount (system preset 25, 50, 75, 100, four types of sample number choice) need to count the sample, hold down the "PCS" key not to let it go, 2 seconds after the screen shows the sample quantity, and then let go "PCS", press "UNITS" can switch different sample number, choose to complete according to "PCS" key to confirm the sample quantity, namely into count; If need to change the number of samples, that is, according to the above steps to reset; In counting state press "UNITS", the system will exit the count, return to normal weighting state display weight value. (this feature is generally don't have to)
bearing calibration
This product already set-up accurate before they go out, but in using the environment temperature and humidity changes obviously (include seasonal climate change) will likely deviation, please follow the steps below to calibrate: under the normal state of weighing, empty on the scale items, and then long hold "UNITS" button, until the display screen shows "CAL" after let go, again according to the "UNITS", "CAL" display correction weight after flashing twice, at this point is placed in the middle of the scale of the weight of corresponding weights, after being show "PASS", automatically return to normal weighting state, after correction. (note: the weight of 100 g scale to use 100 grams of correction, weight of 200 g scale to use 200 grams of correction, and so on)
Â
specification | Capacity | precision | deviation | Minimum scale values |
100G/0.01G | 100g | 0.01g | 0.01-0.03g | 0.04g |
200G/0.01G | 200g | 0.01g | 0.01-0.03g | 0.04g |
500G/0.01G | 500g | 0.01g | 0.01-0.03g | 0.04g |
500G/0.1G | 500g | 0.1g | 0.1-0.3g | 0.4g |
Â
MOQ:500PCS | Sample time:1-3days |
Delivery time:15-20days | Port:Ningbo or Shanghai |
Payment:T/T | CE,ISO |
Bule light
AC/DC power
LCD or LED Display
Kg/lb conversion available
Tare and Auto Zero Tracking
Capacity: 100/200/500g
Packing qty: 100PCS/CTN
G. W: 15kg
Specification:
1. Digit LED
2. Auto Power Shut Off
3. TARE peeled the function PCS counts the function, The UNIT UNIT conversion function, RIGHT background light display.
4. Gross weight, net weight: 114 g / 124 g/units
5. Power supply: 1.5 V (dry cell / 2)
6. A variety of display mode; G/oz/tl/ct, precision: soil (0.5% + of LSD)
7. Products' size: 120.4 mm / 62 mm / 20.3 mm
8. Pallet size: 56.3 mm / 50.2 m





Instructions
Turn on/off:
1. Put electronic scale smooth the surface of the table, and then press ON/OFF button (ON/OFF key), boot screen shows boot screen (backlight will automatically open) at the same time, the "0.00" will be displayed after about 1 second, can be normal use
2. Boot mode, according to an ON/OFF button (ON/OFF button) can be shut OFF the power
3. In order to prolong the service life of the battery, in the boot state, without any operation or display Numbers without any change, will automatically shut off the power supply in 60 seconds
Reset/peeling function:
1. Boot if not shown after the "0.00", press "TARE" button, display zero, can be normal use
2. If you want to use other container to weigh, please put the container on the scale, and then click on the "TARE" button shows that after the "0.00", put items on the capacity of product, display is the actual weight of goods; Get off after container will show a negative number, press "TARE" reset
Unit:
g ,oz,tl,ct
LCD:
Boot mode, according to the "LIGHT" in turn key, can open or close the backlight
tally function
Under the normal state of weighing, placed on the scale amount (system preset 25, 50, 75, 100, four types of sample number choice) need to count the sample, hold down the "PCS" key not to let it go, 2 seconds after the screen shows the sample quantity, and then let go "PCS", press "UNITS" can switch different sample number, choose to complete according to "PCS" key to confirm the sample quantity, namely into count; If need to change the number of samples, that is, according to the above steps to reset; In counting state press "UNITS", the system will exit the count, return to normal weighting state display weight value. (this feature is generally don't have to)
bearing calibration
This product already set-up accurate before they go out, but in using the environment temperature and humidity changes obviously (include seasonal climate change) will likely deviation, please follow the steps below to calibrate: under the normal state of weighing, empty on the scale items, and then long hold "UNITS" button, until the display screen shows "CAL" after let go, again according to the "UNITS", "CAL" display correction weight after flashing twice, at this point is placed in the middle of the scale of the weight of corresponding weights, after being show "PASS", automatically return to normal weighting state, after correction. (note: the weight of 100 g scale to use 100 grams of correction, weight of 200 g scale to use 200 grams of correction, and so on)
Â
specification | Capacity | precision | deviation | Minimum scale values |
100G/0.01G | 100g | 0.01g | 0.01-0.03g | 0.04g |
200G/0.01G | 200g | 0.01g | 0.01-0.03g | 0.04g |
500G/0.01G | 500g | 0.01g | 0.01-0.03g | 0.04g |
500G/0.1G | 500g | 0.1g | 0.1-0.3g | 0.4g |
Â
MOQ:500PCS | Sample time:1-3days |
Delivery time:15-20days | Port:Ningbo or Shanghai |
Payment:T/T | CE,ISO |
Folding Machine With Gliding Bagging
A multifunctional automatic garment folding and packing machine for suit packing needs or multiple garments stacking needs. A wide range of applications, suitable for various types of tops and trousers. A packing machine special for trousers, with automatic crotch folding function, which can be equipped different optional functions to meet different packing requirements.
Garment Folder Machine, Garment Bagging, Cloth Bagging Machine, Bagging Garment Folding Machine
ShenZhen Lingchuang Automated Technology Co.,Ltd , https://www.szlcautos.com